9.2 HEATING/COOLING
CIRCUIT
2
9.2.1 Heating/cooling Circuit 2
A check in a box means that the heating/cooling circuit 2 is on.
9.2.2 Set temp. for Cooling
Setting the desired space cooling water temperature in Cooling Circuit 2.
The desired temperature of Cooling Circuit 2 is set.
9.2.3 Set Temp. For Heating
– without heating curve
Set temperature of space heating water
– without heating curve.
When the heating curve is off, the heat pump operates with fixed space heating water
temperature.
Weather-related control of the heating circuit is off, which can lead to higher heating costs!
9.2.4 Mixing Valve
Service setting.
NOTE:
If the second heating circuit is active and the room thermostat is not used, a wire must be
placed between TH and COM. If a wire is not placed between TH and COM, the heat pump
will heat the buffer tank according to the lower temperature demand.