34
EN
All settings are reset to the settings stored during the last intervention by an authorized
service person.
9.8.8 Switch to Factory Settings
Service setting.
9.9 MODE
SETTINGS
9.9.1 Ambient Temp. To Start Heating
Setting the Ambient temperature to start Heating mode.
Default setting is 18°C.
Example:
The set temperature to start heating is 18 °C.
The heat pump will heat the facility depending on the set values (heating curve or constant
space heating water temperature, depending on the settings), if the ambient temperature
drops below 18 °C.
When the ambient temperature rises above 18 °C, the heat pump will automatically stop
heating the facility.
It will resume heating when the ambient temperature drops b
elow 18 °C.
Note:
To prevent too frequent switches between operation and non-operation, the control unit
monitors the current temperature and temperature within a certain period and decides based
on this whether heating should be activated or blocked.