28
EN
If the fields are green, domestic water heating is on.
If the fields are grey, it means the heat pump is not heating domestic water.
9.4.3 Reheating Function
Feature on/off.
A check in the box means that the feature is on.
The feature enables the setting of a second temperature mode for domestic water heating.
This means that it enables two different temperatures of domestic water at various times in
an individual day of the week.
Setting of a second temperature of domestic hot water corresponds to the parameter
“Reheating Set Temp.”.
9.4.4 Reheating Function Timer
Setting the second timer for the heating of domestic hot water!
If the fields are green, domestic water heating is on.
If the fields are grey, it means the heat pump is not heating domestic water.
9.4.5 Reheating Set Temp.
Setting the desired temperature for the second mode of heating of domestic water.
This temperature will be the default temperature for domestic water heating in the “double
mode”.
The temperature can be lower or higher than the primary setting of the desired domestic hot
water temp.!
Note:
If timers overlap, the heat pump will take into account the higher level of desired domestic
water temperature!
9.4.6
Reheating Restart ∆T Setting
For the second temperature mode for heating domestic water, this parameter is used to set
the DHW restart. The recommended setting is 5 °C.
Example:
Desired domestic hot water temperature is 45 °C, and the DHW restart setting is 5 °C. (45–
5=40).
Heat pump will start reheating domestic water once it drops below 40 °C.
Summary of Contents for Aerogor POWER EVI Inverter 15 A
Page 2: ...EN...