background image

 

 

INDOOR AIR PURIFIER
ION TEC AIR 80

 

Translation of the original operating instructions  

 

Summary of Contents for ION TEC AIR 80

Page 1: ...INDOOR AIR PURIFIER ION TEC AIR 80 Translation of the original operating instructions...

Page 2: ...4 5 UV C lamp 11 6 4 4 6 Operating hours 11 6 4 4 7 Sleep mode panel 11 6 4 4 8 Child safety lock 11 6 4 4 9 Unlock code 12 6 4 4 10 Warning signal 12 6 4 4 11 Touch tone 12 6 4 5 Air output 12 6 4 6...

Page 3: ...ded could result in death or serious injury WARNING Type and source of danger Potentially hazardous situation which if not avoided could result in death or serious injury CAUTION Type and source of da...

Page 4: ...ing normal indoor air In continuous operation the ION TEC AIR 80 ensures a significantly lower aerosol load and inactivates up to 99 7 of filtered viruses and bacteria in the room Pollen germs mould s...

Page 5: ...imbs being crushed or rolled over Keep limbs away from the castor air inlet and air outlet areas Use the lock function to prevent unauthor ised operation see Point 6 4 3 Operation and replacement of f...

Page 6: ...th spent charcoal pads The air purifier will detect a missing charcoal filter insert and display a corresponding message on the operat ing panel The air purifier will switch off after 30 seconds After...

Page 7: ...assigned electrical installation for the electrical connection of the air purifier Proceed as follows 1 Assemble air purifier 2 Remove transport packing protection 3 Insert the mains cable three pin s...

Page 8: ...filter UV C lamps Filter cell Afterfilter Activated charcoal filters Equipment Digitally controlled high voltage technology Energy saving EC fan Touch panel with child safety lock Weekly schedule with...

Page 9: ...ce life of the filter cell the pre filter should be regularly checked for coarse dirt particles and cleaned if necessary Application Group Offices G1 Break room office G1 Waiting room doctor s surgery...

Page 10: ...ound switch Adjuster Back Maintenance interval reset Cleaning interval G1 to G3 Information fields Square fields Input fields In weekly schedule 6 4 Symbol explanation Grey disabled or information Gre...

Page 11: ...tapping the slider control 6 4 4 4 Cleaning interval Group settings The cleaning interval symbol is pressed to set the appro priate group according to air purifier use See Point 6 1 for specification...

Page 12: ...can be programmed for the air purifier It is only possible to switch on the weekly schedule function when the air purifier is off The on off symbol is grey The weekly schedule is enabled or disabled b...

Page 13: ...ing hours have been reached the air purifier will switch off Filter cell cleaning and operating hours reset see filter cell cleaning Point 7 3 By tapping the filter cell symbol the filter cell operati...

Page 14: ...um operating hours have been reached the air purifier will switch off Activated charcoal insert replacement and operating hours reset see charcoal filter pad replacement Point 6 4 By tapping the activ...

Page 15: ...injury from falling maintenance door The maintenance door may slip when opening and lead to personal injury Place the maintenance door flat on a firm and clean surface Do not stand the door upright 7...

Page 16: ...to 90 C hygiene or intensive wash cycle Care should be taken to ensure that the collector plates and spray electrodes are not dam aged by the crockery holders in the dishwasher rack Granule dishwashe...

Page 17: ...isplay must be reset when the unit is restarted a By tapping the charcoal filter symbol in the start menu the charcoal filter operating hours status menu opens This shows the current number of op erat...

Page 18: ...ng has been carried out can the air purifier be restarted by entering the maintenance reset code After replacement dispose of the UV C bulb at the local electrical and electronic waste collection poin...

Page 19: ...Torn wire Faulty filter cell Contact support Error message Filter cell function impaired Possible cause Solution Moisture has not fully dried after cleaning Pre filter dirty Coarse dust particles may...

Page 20: ...acturer s trained professionals 9 3 Spare parts The following information is required when ordering spare parts Designation of spare part Article number Date of manufacture of the unit Quantity See th...

Page 21: ...ocated behind the maintenance door on the inner left hand side of the housing in the fan area 12 1 Serial number The serial number of the air purifier is specified on the rating plate 13 Ordering info...

Page 22: ...Page 22 of 24 14 Circuit diagram...

Page 23: ...Page 23 of 24 15 CE Declaration of Conformity...

Page 24: ...PRO GmbH P O Box 13 10 75033 Oberderdingen GERMANY Phone 49 0 7045 44 81416 Fax 49 0 7045 44 81508 Email service bpro solutions com Internet www bpro solutions com Document No 154 901 Version 1 2 11 2...

Reviews: