Page 5 of 24
2.6
Use in children’s day care centres and
schools
Additional information for children's day care centres
and schools
The information provided here refers to special risks in
children’s day care centres and schools.
NOTICE!
Unauthorised opening of the air
purifier
The standard lock can be opened using a
screwdriver, coin or similarly shaped object.
This prevents unauthorised opening.
A triangle lock is available as an option for
door locking. This secures the unit against
unauthorised opening.
Duty to supervise
Unsupervised operation and movement of the air purifier is
not permitted. Currently applicable legislation on supervi-
sion must be observed. Failure to observe the duty to
supervise may result in improper use or misuse of the air
filter.
Misuse of the air purifier
DANGER!
Danger of tipping
Climbing on the air purifier or using it as a
toy is prohibited.
Nothing may be placed, stored or transported on the air
purifier!
The air purifier must not be used as a climbing aid. There
is a danger of tipping that may result in personal injury.
The air purifier must be secured against rolling away or
moving using all four castor brakes. Misuse may result in
people being trapped or limbs being crushed or rolled
over. Keep limbs away from the castor, air inlet and air
outlet areas.
Use the lock function to prevent unauthor-
ised operation, see Point 6.4.3
Operation and replacement of filter components
Filter components may only be operated or replaced by
trained personnel. Children must be kept away from the air
purifier and components during replacement.
Keep children away from any dirt (e.g. pieces of the char-
coal pads) and remove and dispose of immediately.
3 Functional
description
The ION TEC AIR 80 air purifier is a powerful filter system
for indoor air and reliably removes fine dust, pollen, bacte-
ria, viruses, germs, mould spores, nicotine and smoke. It
reduces VOCs and odours.
Filtered viruses and bacteria are inactivated through the
use of UV-C irradiation. The filter components do not
present an increased risk of infection.
3.1 Unit
structure
Illustration 1: Air purifier
The air from the room is drawn in at the bottom, filtered
and released back into the room clean via the upper air
outlet.
It is operated using a touch panel. Here, running sched-
ules (timer, weekly schedule), air volume settings and
other individual configurations are made. The contamina-
tion level of the filter stages is displayed through colour
coding (service traffic signal system). The touch panel is
equipped with a child safety lock.
Air outlet
Air outlet
Touch panel
Maintenance door
at back
Air intlet