67
6.15 OTHER
OPTIONS
These settings can be accessed only with service permission level.
6.15.1 MOTORIZED DIVERTING VALVE SWITCHING TIME
Switching time of the diverting valve in minutes if the switching time of the diverting
time is longer than the default setting (1min) change this value according to the
diverting valve specification.
6.15.2 POWER ON TIME FOR MOTORIZED DIVERTING VALVE
Default setting: ALWAYS WITH POWER (set to 0). It determines how long will the
diverting valve have power in switching to sanitary water.
6.15.3 REFRIGERANT RECYCLE FUNCTION
This is used for pumping the refrigerant back to outdoor unit. When turned on, it starts
to count down the running time of this function (600s). When the
Refrigerant
Recycle Function
is active, all safety features are disabled. You can stop this
function by tapping on it again.
6.15.4 CONTROL PANEL BACKLIGHT LIGHT
Here you can adjust the time the display is turned on in these steps:
-
Always on
-
3 min
-
5 min
-
10 min