61
Disabled
- if there is a fault on the Heat Pump, so that the compressor cannot start, the Heat
pump
will not
switch to emergency operation, but it will just stop working until the fault is
canceled. In this case, the house and the DHW may cool too much.
6.12
WATER
PUMP
SETTINGS
6.12.1 Circulation Pump P0 Type
Setting the controlling type of the Circulating pump P0.
P0
=
Internal circulating pump
– Grundfos UPM GEO 25-85
The Internal circulating pump is controlled with PWM signal. In normal conditions, the signal
is constant (according to parameter 6.11.2), only during Start-up when the system water
temperature is low, the circulating pump runs with low speed to increase the condensing
temperature
– Condensing temperature control.