30
3.2 AEROGOR
ECO
COMPACT
INVERTER
10A,
13A
3.2.1 INDOOR UNIT
A
HEAT PUMP POWER SUPPLY (FUSE
– 20 A 1P C)
B
INTERNAL ELECTRICAL HEATERS POWER SUPPLY (FUSE
– 3x10 A 1P C)
C
POWER SUPPLY FOR ADDITIONAL ELECTRICAL HEATER FOR DHW TANK
–
DEPENDING ON THE TYPE
D
INDOOR TO OUTDOOR POWER CONNECTION (230 V)
– 3x2,5
𝑚𝑚
2
E
CONSTANT 230 V RESERVE
– MAX. LOAD 100W
F
CIRCULATING PUMP
– HEATING CIRCUIT 1
G
CIRCULATING PUMP
– HEATING CIRCUIT 2
H
CIRCULATING PUMP FOR DHW (230 V on P3 during DHW operation)
I
ADDITIONAL ELECTRICAL HEATER FOR DHW TANK
J
DIVERTING VALVE
– DHW MODE WITH POWER
K
MODE SWITCHING SIGNAL (see page 65)
L
INDOOR TO OUTDOOR COMMUNICATION
Cable included in the package
– 3x0,75
𝒎𝒎
𝟐
Shielded
M
MIXING VALVE 1 (24 V DC Power supply, 0
– 10 V DC Signal)
N
MIXING VALVE 2 (24 V DC Power supply, 0
– 10 V DC Signal)
O
ELECTRICAL UTILITY LOCK
P
EXTERNAL SWITCH INPUT FOR COOLING MODE (0/1) (see page 55)
R
EXTERNAL SWITCH INPUT FOR HEATING MODE (0/1) (see page 55)
Q
EXTERNAL SWITCH INPUT FOR HIGH TEMPERATURE DEMAND (0/1) (see page
60,61)
Summary of Contents for Aerogor ECO COMPACT INVERTER 10A
Page 2: ......
Page 88: ...81 10 WIRING 10 1INDOOR UNIT ALL INVERTERS REFERS TO AS LINE OF HEAT PUMPS...
Page 89: ...82 INDOOR UNIT ALL INVERTERS...
Page 91: ...84 10 3OUTDOOR PCB ECO INVERTER...
Page 92: ...85 OUTDOOR PCB ECO INVERTER...
Page 93: ...86 10 4DRIVE FOR EEV ECO INVERTER 13A and ECO COMPACT INVERTER 13A...
Page 94: ...87 10 5OUTDOOR UNIT POWER EVI INVERTER 15A 18A...
Page 95: ...88 OUTDOOR UNIT POWER EVI INVERTER 15A 18A...
Page 96: ...89 10 6OUTDOOR UNIT DRIVE AEROGOR POWER EVI 15A 18A...