90
www.glomex.it
DANUBE “NEO”
(R500N - R500N/DCSS)
ENGLISH
14.3 REPLACING THE POWER SUPPLY
PROTECTION FUSE
In case the fuse on the power supply line has
blown, proceed as follows to replace it:
- Turn off the decoder, the TV set and make sure
that the switch on the control unit is set to OFF.
- Remove the control unit from the wall-mounting
bracket, open the box by loosening the screws.
- OPTIONAL: (in case of built-in installation):
remove the wall-mounting plate (see
loosen the screws and remove the built-in
control unit.
- Disconnect the power supply cable from the
battery.
- Remove the blown fuse from its seat indicated in
and replace it with a new one (
type T
3.15A L 250 VAC 5x20
, i.e. delayed-action tube
fuse, with 5 mm diameter and 20 mm length,
3.15 A rated current and 250 V rated voltage).
- Connect the power supply to the battery again.
- Reinstall the rear cover onto the control unit.
- OPTIONAL (in case of built-in installation):
insert the control unit into the wall, reinstall the
fastening screws and the installation plate.
S
WARNING
In case the fuse blows again, a short circuit on the
coaxial cable or on the power supply cable could
be the cause.
Check that the cables are not short-circuited.
S
DANGER
Do not supply the antenna by connecting the 2
wires of the positive pole without using the fuse.
A fire could break out as a result of a short circuit.
Fig. 51
Summary of Contents for DANUBE NEO R500N
Page 2: ......
Page 4: ...DANUBE NEO R500N R500N DCSS 2 www glomex it ITALIANO...
Page 34: ...32 www glomex it ITALIANO DANUBE NEO R500N R500N DCSS Fig 42...
Page 52: ...DANUBE NEO R500N R500N DCSS 50 www glomex it ENGLISH...
Page 82: ...80 www glomex it DANUBE NEO R500N R500N DCSS ENGLISH Fig 42...
Page 100: ...DANUBE NEO R500N R500N DCSS 98 www glomex it FRAN AIS...
Page 130: ...128 www glomex it DANUBE NEO R500N R500N DCSS FRAN AIS Fig 42...