Pag. 19
3.1 ROUTINE MAINTENANCE
3.
CLEANING AND MAINTENANCE
At the end of the working day, clean the appliance, both for reasons of hygiene and to prevent operating faults.
Do not clean the appliance with direct or high-pressure jets of water and do not use metal pads, brushes or scra-
pers in normal steel. If necessary, use stainless steel pads, but do not rub them against the grain of the metal of
the appliance.
Use warm soapy water on steel surfaces and then rinse in plenty of water and dry with a soft cloth. Maintain the
shine by regular polishing with a normal liquid polish.
Do not wash the work top or floor with hydrochloric acid.
3.2 SPECIAL MAINTENANCE
At regular intervals (at least once a year or more often in cases of frequent use), service the appliance thoroughly.
This includes checking the gas circuit, checking parts for damage and if necessary lubricating the taps if they are
difficult to use. Contact a specialised and experienced technician. A maintenance contract should be taken out
with a centre approved by the company.
TECHNICAL SPECIFICATIONS TABLE FOR CATEGORY II2H3+ GAS FRYERS
THE MANUFACTURER RESERVES THE RIGHT TO WITHOUT NOTICE MODIFY THE FEATURES OF THE
APPLIANCES DESCRIBED IN THIS MANUAL.
THE MANUFACTURER ACCEPTS NO RESPONSIBILITY FOR HARM CAUSED BY INCORRECT INTERVEN-
TIONS, TAMPERING WITH THE APPLIANCE, MISUSE, POOR MAINTENANCE, NON-COMPLIANCE WITH
CURRENT REGULATIONS AND INEXPERT USE.
3.3 CONTROL AND SAFETY DEVICES
If the appliance is not used for a long time or if it does not work or works irregularly, the gas stopcock upstream
of the appliance must be shut off.
All the parts of the appliance that are subject to wear can easily be accessed from the front of the appliance by
opening the door or after removing the front.
All the couplings use a dado and bicono, so great care must be taken in handling these components. If the part
is damaged during dismantling or reassembly it must be replaced with a new one.
If the oil exceeds the set temperature the safety thermostat breaks the contact with the thermocouple. To restart
the appliance, open the door and press the red pusch-button.
Warning. As the safety thermostat may have been triggered by a faulty gas valve or thermostat, any faulty parts
must be replaced by an authorised technician before the appliance is started up again.
Mod.
Rated
Output
Tank
Capacity
Pressure in mbar
G30/G31 = 30/37
G20 = 18/20
NOZZLES MAIN
BURNER Ø
NOZZLES PILOT
BURNER Ø
G30
G20
G30
G20
G31
G31
kW(P.C.I.)
Lt
1/100mm
1/100mm
1/100mm
921PGC
19
21
165K
300K
9,5 mbar
20
Reg.
942PGC
21 + 21