64
Operation
GBF-2-GVH Ventless Fryer
When the
[WASH/CHECK]
lights turn
ON
, the E.A.C. Filter system has entered an alarm state and has stopped
functioning. After approximately two (2) minutes, a beeping tone alarm will begin to sound and shortly thereafter,
the
[APPLIANCE POWERED]
light will turn
OFF
and power to both Fryers’ heating elements will be shutdown.
The following steps may be tried in an attempt to clear the alarm:
1. Turn
OFF
Hood Power Switch.
2. Remove the E.A.C. Cell and clean as described in
Section 5.02.4.2
.
3. Inspect the Filter Cell for broken or missing ionizer wires, bent fins, or other damage. Ionizer wires are
replaceable
(P/N 21153)
; bent fins may be straightened by hand. An excessively damaged Cell (broken
insulators, broken frame, etc.) will need to be replaced.
4. Inspect the Filter Contact Board inside Hood. Clean any grease accumulation away with a mild degreaser
solution (Simple Green) and dry thoroughly.
5. Replace Filter Cell (
see Section 5.02.2.3
) and restart Hood. If the condition persist, contact a qualified service
technician and have the system evaluated and repaired.
5.02.2.4
E.A.C. Filter Operation - continued
5.02.3
Hood Alarms
5.02.3.1
Hood Alarm Table
Alarm Sound
What Happens
Filter
Affected
Cause
Solution
See Section
Continuous tone
Red
[CHARCOAL OR BAFFLE FILTER
CLOGGED]
light
ON
; power to both
Fryers heating elements
OFF
; amber
[APPLIANCE POWERED]
light
OFF
.
Charcoal
Filter is
dirty or
otherwise
clogged
Replace Filter
5.02.2.2;
5.02.2.3;
5.02.4.4
Continuous tone
Red
[CHARCOAL OR BAFFLE FILTER
CLOGGED]
light
ON
; power to both
Fryers heating elements
OFF
; amber
[APPLIANCE POWERED]
light
OFF
.
Baffle
Filter is
dirty or
otherwise
clogged
Remove Filter
and clean
5.02.2.2;
5.02.2.3;
5.02.4.1
Beeping tone
[CHECK/WASH]
lights
ON
; alarm
sounds after approx. 2 minutes; within
several seconds, power to both Fryers
heating elements is turned
OFF
; amber
[APPLIANCE POWERED]
light turns
OFF
.
E.A.C.
Filter is very
dirty or
other faults
Clean cell.
Replace or
repair cell; call
for service
5.02.2.2;
5.02.3.3;
5.02.4
.2
The integral Ventless Recirculating Hood is equipped with a system of interlocks designed to prevent operation of
the Hood or Fryers if the air cleaning system is not operating properly. This section explains the alarm conditions
and steps required to clear an alarm.
Summary of Contents for GBF-2-GVH Series
Page 2: ......
Page 4: ......
Page 12: ...x ...
Page 16: ...4 Introduction GBF 2 GVH Ventless Fryer ...
Page 26: ...Installation 14 GBF 2 GVH Ventless Fryer ...
Page 28: ...16 Overview 1 GBF 2 GVH Ventless Fryer 3 01 Baskets Auto Basket Lifts Optional 2 4 3 Hidden ...
Page 36: ...24 Overview GBF 2 GVH Ventless Fryer 3 05 Hood Control Panel 3 5 2 4 1 6 7 8 9 10 ...
Page 38: ...26 Overview GBF 2 GVH Ventless Fryer Not Shown 3 06 Hood Front Filter Chamber 3 5 2 4 1 6 7 ...
Page 46: ...34 Overview GBF 2 GVH Ventless Fryer ...
Page 52: ...40 GBF 2 GVH Ventless Fryer Pre Operation Tests ...
Page 93: ...81 Operation GBF 2 GVH Ventless Fryer ...
Page 103: ...91 ...
Page 111: ...99 Troubleshooting GBF 2 GVH Ventless Fryer ...
Page 112: ...100 Troubleshooting GBF 2 GVH Ventless Fryer ...
Page 128: ...116 Parts List GBF 2 GVH Ventless Fryer 3 1 5 4 2 8 9 7 10 6 A 8 09 Filter Pan ...
Page 134: ...122 Parts List GBF 2 GVH Ventless Fryer 8 12 Hood Filter Fan Compartment 1 2 3 4 5 6 7 8 ...
Page 136: ...124 Parts List GBF 2 GVH Ventless Fryer 2 1 3 4 8 13 Under Hood Components ...
Page 138: ...126 Parts List GBF 2 GVH Ventless Fryer ...
Page 139: ......