Terminal
#
wire function
1
‘A’ Optoisolated Trigger
2
3
‘B’ Optoisolated Trigger
4
5
Error/Status Output
6
7
External Output Enable
8
9
'Battery' input
10
11
Power Supply Ground
12
Power Supply Positive (24 VDC)
1)
'A' Trigger Input
2)
'A' Trigger Input
3)
'B' Trigger Input
4)
'B' Trigger Input
The two trigger
inputs will accept
voltages from 5 vdc to
24 vdc. The inputs are
optically isolated from the rest of the Br-EFB's circuitry and non-polarized.
It doesn't matter which terminal is wired to the negative or positive lead.
You can't wire it backwards, because it will work either way.
Switch 'A'
Switch 'B'
Gnd
Battery -
B
Enable
External
Output
Low)
Error/ (Active
+24v
Heart
2.1mm
24 vdc
Power
Input
Input
A B
Gilderfluke & Co. • Burbank, California
Rs-422
DMX-512
In
'thru'
In
'thru'
100
Activity
10/100
Ethernet
Gilderfluke & Co.• 205 South Flower Street • Burbank, California 91502 • 818/840-9484 • 800/776-5972 • fax 818/840-9485
Br-EFB Manual / May 22, 2018 3:28 PM / page 28 of 142