Br-EFB PID Configuration (Text Menus)
This menu is used to manually configure the PI & D settings for a feedback loop.
You can also access the Wizards to determine the ‘phasing’ of the servoloop and use
the PID wizard if you want the Br-EFB to set up the PID settings for you.
Br-EFB PID Menu
This menu is accessed by selecting the 'm) more' selection from any other menu. If
the 'address to test' is off-board, the user will be prompted for an on-board address.
The 'n) Next', 'l) Last)' and 'j) address to test' are all limited to the four on-board
addresses. To exit this menu:
1) Use the 'm) More...' command to save changes and go to any other menu.
2) Hit the <ESCape> key. Changed values will be discarded, and you will be
returned to the previous menu.
3) Hit the <RETURN> key. Changed values will be saved, and you will be
- Gilderfluke & Co. - Electronic Feedback Card - version 1.00 - copyright 2018 -
Uptime: 99:23:59:59, Serial Address: 123, IP: 192.168.2.113
ADL: Lorenzo (2015-12-25 0744) w/503 channels @ 12 Offset
Show #4 (of 210) Night Mode looping @ 00:19:49.22
DeviceName PID Settings
1) axis 0: Enabled +---------+--------+--------+--------+-------+-----
2) proportional (P) gain | DMX_512 | Prop. | Int. | Der. |Voltage| Rev
3) integral (I) gain | Address | Gain | Gain | Gain | Limit | Out
4) derivative (D) gain +---------+--------+--------+--------+-------+-----
5) limit valve voltage -> | OutputName / FigureName | | |
6) reverse axis output -> | 123 [0] | 1.000 | 0.000 | 0.000 | 10.00 | No
7) compliance settings +---------+--------+--------+--------+-------+-----
8) following errors | OutputName / FigureName | | |
9) A/D Range: +/-10 volts | 125 [1] | 1.000 | 0.000 | 0.000 | 10.00 | No
0) PID adjustment wizards +---------+--------+--------+--------+-------+-----
u) min/max/jog w/keypad | OutputName / FigureName | | |
j) address to test: 123 | 128 [2] | 1.000 | 0.000 | 0.000 | 10.00 | Yes
k) testing: none +---------+--------+--------+--------+-------+-----
resolution: 8 Bits | OutputName / FigureName | | |
figure: FigureName | 130 [3] | 1.000 | 0.000 | 0.000 | 10.00 | No
output: OutputName +---------+--------+--------+--------+-------+-----
m) More, n) Next, l) Last, i) Info, o) def, p) Play, h) Halt, v) Verify, x) eXit
Command-
Gilderfluke & Co.• 205 South Flower Street • Burbank, California 91502 • 818/840-9484 • 800/776-5972 • fax 818/840-9485
Br-EFB Manual / May 22, 2018 3:28 PM / page 97 of 142