When you are satisfied with your adjustments, just hit the <Carriage Return>.
If you don’t want to save your settings, hit the <ESC>ape key to restore the
original values.
W) Set Analog Endpoints
The endpoints can only be set for the on-board 0-10 volt analog outputs. A
new output address will be requested if the currently selected 'Output to Test &
Adjust' is not one of the on-board ones.
This command is used to adjust the endpoints of the sixteen analog outputs.
Unless you already know the numeric values you want to set the endpoints to,
the ‘Set Min/Max/’Jog’ using Keypad’ is a much easier way of setting these. Use
it if you can.
The analog outputs normally sweep between 0 and 10 Volts DC. By using
these commands you can set either endpoint to anywhere between 0 and 10
volts for a reduced or reversed analog output swing. If you want to invert the
voltage swing of any output, all you need to do is set the lower limit to a higher
level than the upper limit. The endpoints for all sixteen outputs is displayed in the
'Minimum Scale'/'Maximum Scale' columns on the display.
As an example of the use of the analog endpoint adjustments, if you wanted
to set the voltages on a channel to sweep from approximately 25% to 75% of full
scale. From the chart you would see that the values that would be entered are
64 and 192.
To set the endpoints, first clear the endpoints to the two extremes (0%/0/00h).
Then use a Togglodyte, Programming Console, or the 'Force Output to a Value'
command to find what values set the proper endpoints for the output. You can
then enter these numbers into the endpoints for this output.
N) Next
This moves the ‘Output to test & Adjust’ arrow down by one line. This
command limits you to channels stored in the AutoDownload file. After the
Br-EFB’s last channel, it will jump back up to the first. If there is no
AutoDownload file loaded, then it assumes that all channels are 8 bit resolution
analogs, and limits you to the DMX-512 universe.
If there have been changes made in the settings for the selected channel,
they will be saved before the Br-EFB steps to the 'next' channel.