b) external show control data is being received through the
DMX-512, serial or ethernet ports and processed by the
Br-EFB
3. This LED will be lit solid
RED
if:
a) The Br-EFB is powered up
b) The 'External Output Enable' input does NOT have a
voltage to enable the Br-EFB's ServoValve/Motor Controller
outputs
c) An internal show is not running and no external show
control data is being received and processed by the Br-EFB
4. This LED will be flashing
RED
at the normal heartbeat flash rate if:
a) The Br-EFB is powered up
b) The 'External Output Enable' input has a voltage applied to
it to enable the Br-EFB's ServoValve/Motor Controller
outputs
c) There is an error condition reported on one or more of the
servo channels. The Axis that are in error will have their
individual error LEDs flashing to identify the source and type
of error.
d) An internal show is not running and no external show
control data is being received and processed by the Br-EFB
5. This LED will be flashing
RED
at the current frame rate if:
a) The Br-EFB is powered up
b) The 'External Output Enable' input has a voltage applied to
it to enable the Br-EFB's ServoValve/Motor Controller
outputs
c) There is an error condition reported on one or more of the
servo channels. The Axis that are in error will have their
individual error LEDs flashing to identify the source and type
of error.
d) Either:
Gilderfluke & Co.• 205 South Flower Street • Burbank, California 91502 • 818/840-9484 • 800/776-5972 • fax 818/840-9485
Br-EFB Manual / May 22, 2018 3:28 PM / page 23 of 142