Passport CPC Overview
Forecourt Configuration
Page 10
MDE-4318D Competitive Pump and CRIND (CPC) Hardware/Software Start-up and Service Manual · May 2010
Enter or select data for the following fields:
•
Payment Terminal Type
: Select the type of payment terminal from the drop-down list
(for example, Wayne CAT).
•
CRIND/CAT LoopID
: Enter the loop ID for the payment terminal.
Note: Payment terminals cannot share the same communication loop as a dispenser.
•
CRIND/CAT DeviceID
: Enter the device ID for the payment terminal. This is the
physical address of the position as programmed within the payment terminal’s electronics.
Ensure that the proper device ID is mapped to the appropriate fueling position in the “No.”
column.
Note: This CAT Device ID may not always be identical to the Device ID of its associated
fueling position.
•
Data Control Board (DCB) Address
: If an RFID device is in use for this fueling
position, enter the address of the DCB in this field. Valid entries are 1 to 16.
Note: Each DCB requires a unique address.
•
DCB Side
: If an RFID device is in use for this fueling position, specify the side of the
DCB used by that ID.
•
DSM
: Select this checkbox if a DSM is used to process outside debit transactions. If there
is no DSM in use, then do not select this checkbox.
Note: Use a configuration report from an existing POS system to obtain DCB data. If
configuration is not available, the DCB address and side may have to be obtained
directly from the RFID hardware inside the dispenser.
3
Click
Update List
to save your entries.
4
Perform one of the following:
• To program another payment terminal, repeat steps
and
• To continue, click the
Product