27
SECTION 4 - INSTALLATION
4
MDE-5224F
Grounding
To make grounding connections to the chassis:
1
Route the two Braid Terminal Ground Cables [M04431A002 (one from the UX300 and one from the
UPM)] on each Advantage left-hand side door under the printer tray and secure on the underside with
the cable push mount provided.
2
Secure the two ring terminals to the support rail using a M00417B101 M5 Screw as shown in
.
Figure 14: Securing Ring Terminals
Support Rail
3
for side B of the unit.
Power Supply Grounding Connection
To make grounding connection for the power supply, connect the M04431A002 Cable between the AFP
assembly and the power supply support rail using a M00417B101 Screw.