21
SECTION 4 - INSTALLATION
4
MDE-5224F
The following table lists wiring details for MOC mode:
Note: There are no cables connected to P300.
For Generic CRIND
• CRIND two-wire must be connected to the blue/yellow wires. Pump two-wire must be connected to
the red/yellow wires.
• J4 must be out.
• If high-speed connectivity is used, J3 must be ON.
• The pump two-wire input must be connected to P303.
Figure 9: Generic Type Configuration Two-Wire
Physically Connecting Communications Wiring
Connecting and Configuring Forecourt
To make forecourt connections and configuration:
1
Locate M2993A005 Cable. Attach the 5-pin connector to P300. This is the CRIND and pump forecourt
connection.
2
For Generic CRIND, wire nut the blue/yellow wiring to B9 and B19 and the red/yellow wiring to A9 and
A19.
3
For MOC CRIND, wire nut the red/yellow wiring to A9 and A19.
4
For MOC CRIND, insert J4; remove it for Generic CRIND.
Cable Part
Connector
Color
Description
M02993A006
P333.1
Yellow
High Speed
M02993A006
P333.2
Yellow
High Speed
M02993A006
P333.3
Red
CRIND+
M02993A006
P333.4
Blue
CRIND-