25
SECTION 4 - INSTALLATION
4
MDE-5224F
CRIND to Pump Communication
The Advantage Series Units Built After 1997
For The Advantage Series units built after 1997, connect P403 on the M12852A002 Cable from P303 on the
AFP/DCM2 to the P402 connector on the pump board.
The Advantage Series Units with Modular Electronics Built Before 1997
1
For The Advantage Series units with modular electronics built before 1997, locate P402 and splice in
the M12852A002 Cable. This is because P402 is the most accessible point to intercept the field wiring.
2
Cut the larger connector off of M12852A002 Cable and splice it into field wiring conduit side of P402
(see
).
Figure 12: Wiring Connections for The Advantage Series Units (Built Before 1997)
F
ield Wir
ing
Conduit
Cut (2)
Wire Nuts (2)
M12852A002
P402 Connector
Modular
Pump Board
P303 on
AFP/DCM2