13
SECTION 4 - INSTALLATION
4
MDE-5224F
Connecting Cables for AFP Assembly
For cable block diagram, refer to
Cable routing is critical. It is very important to route and dress the cables
properly. Exercise care in routing the cables, keeping in mind that the
door(s) opens and closes for service. The cables must be dressed neatly.
Ensure that there is no interference after the cables are connected and
routed. Keep the ground cables isolated from the rest of the door cables.
IMPORTANT INFORMATION
To make the AFP/DCM2 assembly connections:
Side A
On the side A of the unit, connect the following cables from the door to the AFP/DCM2 assembly:
1
Connect the 24 VDC Power Cable (M14340A002) to J301A on the 24 VDC Power to AFP/Fuse Board
Cable (M12777A003) on the AFP assembly.
2
Connect the 24 V printer power cable to one of the headers on the fuse board located on the
AFP/DCM2 assembly.
3
Connect the P202 connector on the PIP3 to P302A connector on the AFP with M14339A001 AFP Serial
Cable.
4
Connect the Category 5 (CAT5) cable from the UPM to J305A RJ-45 connector on the AFP/DCM2
assembly.
5
Connect the CAT5 cable from UX300 card reader to J305B RJ-45 connector on the AFP/DCM2
assembly.
Side B
On the side B of the unit, connect the following cables from the door to the AFP/DCM2 assembly:
1
Connect the M14340A002 UPM Power Cable to J301B on M12777A003 Cable on the AFP/DCM2
assembly.
2
Connect the 24 V printer power cable to one of the headers on the fuse board located on the
AFP/DCM2 assembly.
3
Connect the P202 connector on PIP3 to AFP/DCM2 serial cable to P302B.
4
Connect the CAT5 cable from UPM to J305C RJ-45 connector on the AFP/DCM2 assembly.