MDE-5224F
28
SECTION 4 - INSTALLATION
4
AC Power
The Advantage Series Units Built Prior to 1999
To make AC power connections for The Advantage Series units built prior to 1999:
1
Install the AC Power Adapter Cable (R20580-G3) by inserting it between J601 and P601 (see
).
2
Plug the AC power input from the AFP assembly into P601 of R20580-G3 Cable.
Figure 15: Plugging AC Power Input from AFP to R20580-G3
The Advantage Series Units Built After 1999
To make AC power connections for The Advantage Series units built after 1999:
1
Locate the AC Adaptor Cable Assembly (T19612-G2) from the pump power supply located across the
bottom of the electronics cavity.
2
Plug the 3-pin power AFP connector into an available connection.
3
Ensure that all AC connections are paired as black-to-black, white-to-white, and green-to-green.
Note: After all the cables have been routed from the doors to the interior of The Advantage Series unit,
ensure to route the cables to avoid pinching.