Check:
1. Switch over to the "Automatic"
au
program.
2. Set door to the "Winter" operating mode by simultaneously pressing
keys
and .
3. Check position of reduced opening width with a tape measure by actuation or with
"reduced continuous open".
Cancelling Learning mode
➮
Press the Service key and the
key at the same time.
5.4
Air lock or vestibule via a program selector (with DCU1
only)
The air lock and vestibule functions are only available with standard sliding doors
(DCU1).
Air lock: Two sliding doors use the same program selector. A door only opens when
the other one is closed.
Vestibule: Two sliding doors use the same program selector.
Commissioning of an air lock or
vestibule system
1. Commission the inner door (main controller) as with a single system.
At this time, the outer door (secondary controller) is de-energised.
2. Switch off the inner door.
3. Commission the outer door as with a single system. During this time the inner door
is de-energised.
4. In the menu item
sl
, set the following value at the outer door
01
for a secondary controller (air lock) or
02
for a secondary controller (vestibule).
5. Check whether the value
00
is switched on for inner door in the menu item
sl
.
6. Switch off the system and start both systems simultaneously.
These functions are not allowed with sliding doors in escape paths
(DCU1-2M).
With the air lock and vestibule, the program selector only displays the fault
messages of the main controller.
•
Only connect the power supply of the display program switch to the
internal door during operation of both systems.
•
Supply the display program switch with the power of the outer door during
outer door commissioning.