ECturn/ECturn Inside
13
Safety sensor close and open
5.2.3 Monitoring closing
X
Set the parameters:
à
s1
(safety closing) to
01
for “SIS” or to
0 2
for “SIS
and K”.
à
s3
(safety opening) to
0 0
for “no SIO”.
à
Te
(testing) to
0 2
for “testing with GND”.
1
SIS
11
1
GND
4
24VSENS
10 TST
SIS
-UB
+UB
COM
+
SIO
60 mA
Test
SIS
GC 342
BGS
BN
GN
YE
WH
PK
GY
BU
RD
1
Door transmission cable
5.3 Safety sensor GC 334
à
GC 334 module, mat. no. 126410
à
Accessories:
à
GC 334 interface, mat. no. 128306
à
Spot finder, mat. no. 112321
à
max. 6 modules in series
X
Follow the installation instructions.
5.3.1 Monitoring closing and opening
X
Set the parameters:
à
s1
(safety closing) to
01
for “SIS” or to
0 2
for “SIS
and K”.
à
s3
(safety opening) to
01
for “SIO”.
à
Te
(testing) to
0 2
for “testing with GND”.
X
Configure GC 334 modules:
à
Hinge side: DIP1 = ON
à
Opposite hinge side: DIP1 = OFF
SIS
1 GND
11 SIS
10 TST
4 24VSENS
1 GND
13 SIO
10 TST
4 24VSENS
SIO
VT
PK
GC 334 BS
WH
YE
GN
-
+
BN
BU
-
+
RD
GC 334 Module BS
GC 334 Module BGS
60mA
1
1
Door transmission cable