Configurable input
11 Configurable input
PE is a configurable input. The function can be set via the service menu (see chapter 21, “Parameter menu”).
ECturn: The signal is connected to input PE1 - terminal 51.
ECturn Inside: The signal is connected to input PE2 - terminal 52.
11.1 Sabotage
à
The configurable PE input can be used as a sabotage input
e.g. for monitoring a mechanical contact with sabotage
contact.
à
When the switch housing is closed, the sabotage contact
is closed, 24 V is applied to the sabotage input.
à
When the key switch housing is opened, the sabotage con-
tact is opened, 0 V is applied to the sabotage input.
à
In this case activation via the mechanical contact is ignored.
à
Error 32 (Sabotage) is indicated.
à
If the PA output is configured as a fault output, the out-
put contact is closed.
à
Activation via KB is only possible again after the mode
of operation has been changed with closed sabotage
contact.
X
Set the parameters:
à
Set
e1
or
e2
(configurable input) to
01
for “sabotage”.
à
If necessary, set
a1
(configurable output) to
0 2
for “fault”.
ECturn
ECturn Inside
51 PE1
1
GND
2 24V
PE
52 PE2
2
24V
PE
11.2 Switch function
à
Upon activation, the output of the button is closed (24 V
applied to the PE input).
à
The first switch contact opens the door and the next closes
the door. For the setting switch function with closing after
the hold-open time, the door closes automatically after the
hold-open time elapses if it was not closed via the push
button beforehand.
ECturn
ECturn Inside
51 PE1
1
GND
2 24V
PE
52 PE2
2 24V
PE
X
Set the parameters:
à
Set
e1
or
e2
(configurable input) to
0 2
for “switch function” or to
0 3
for “switch function close after hold-
open time”.
11.3 NA mode of operation
à
The configurable PE input can be used as the input for NA
mode of operation.
à
When the night mode switch is activated, the contact is
closed (24 V applied to the PE input).
à
The door closes and changes to the NA mode of operation
as soon as the switch is pressed.
à
The door remains in the NA mode of operation as long as
24 V is applied to the PE output. It is not possible to change
the mode of operation via a programme switch.
X
Set the parameters:
à
Set
e1
or
e2
(configurable input) to
0 4
for the “mode
of operation NA” function.
ECturn
ECturn Inside
51 PE1
1
GND
2 24V
PE
52 PE2
2
24V
PE