![GEZE ECturn Wiring Diagram Download Page 42](http://html.mh-extra.com/html/geze/ecturn/ecturn_wiring-diagram_2219106042.webp)
ECturn/ECturn Inside
42
Error messages
DPS
TPS
Service LEDs Error
group
Cause
Behaviour of the drive
5 4 3 2 1
3 2
● ○ ○
○
●
*
● ● ● ●
Sabotage Sabotage active
The activation to KB is suppressed.
The error is deleted as soon as the
mode of operation is changed and
the Sabotage input is inactive.
3 4
x
x
x
x
x
*
○ ● ● ○
Keypad
pro-
gramme
switch
Monitoring only if TPS was
connected to the control unit
when the operating voltage
was switched on.
Drive remains in operation.
The error is deleted as soon as the
TPS responds again.
41
● ○ ●
○
○
*
○ ● ○ ○
Safety
sensor
open
Testing safety sensor open
is faulty
Door closes with normal speed.
Retests 10 times in the closing position.
Retests after every change in mode
of operation or after every activation.
As long as the error is active, the
door is only accessible manually.
Activation longer than 4 min Door closes with normal speed.
As long as the sensor is active, the
door opens slowly.
As soon as the signal is inactive
again, the error is deleted.
4 5
○ ○ ○
●
●
*
● ○ ● ●
Control
unit tem-
perature
Control unit overheated
From 85 °C the hold-open time
is extended.
47
● ● ○
○
●
*
○ ● ● ●
Control
unit tem-
perature
sensor
Internal error.
Thermal sensor on the con-
trol unit defective
Drive remains in operation.
4 8
○ ○ ○
●
●
*
● ○ ● ●
Motor
tempera-
ture
Motor temperature too high Motor relay is open.
6 0
● ● ○
○
●
*
○ ● ● ●
Control
unit
Internal error
Door leaf is braked by the motor.
Motor relay is opened.
The generator brake is active as long
the mains voltage is applied.
61
○ ● ●
○
○
*
● ● ○ ○
Recharge-
able bat-
tery
Rechargeable battery
discharged.
Rechargeable battery voltage
<17 V
If mains voltage is available, the drive
remains in operation.
If there is no mains voltage available
(rechargeable battery operation),
the drive switches off.
x .x
○ ○ ●
○
●
- - - - - Position is
unknown
After supply voltage is returned Initialisation with reduced speed.
Mode of operation LED flashes yellow
only with ECturn Inside:
1 4
x
x
x
x
x
*
● ● ● ○
Pro-
gramme
switch
Broken MPS cable
Last operating status is retained.
○
LED off
●
LED on
*
LED5 flashes with 10 Hz
-
no display
x
Display undefined