![GEZE ECturn Wiring Diagram Download Page 34](http://html.mh-extra.com/html/geze/ecturn/ecturn_wiring-diagram_2219106034.webp)
ECturn/ECturn Inside
34
Commissioning and service
20 Commissioning and service
Commissioning and service can be effected either via the display programme switch or the buttons S1 and S2,
see chapter 21, “Parameter menu”.
20.1 Display programme switch
The DPS can be used for commissioning and servicing (mat. no. 151524);
à
for changing the drive parameters
à
for teaching the drive
à
for diagnosis
Modes of operation
Service mode
OFF
1
2
1
Service key
2
Position unknown
N a
Night mode
×
Cancel and return to first
menu level
ls
Without function
Confirm
a U
Automatic
Scroll up
Increase value
D O
Hold open
Scroll down
Reduce value
O f
OFF
Service button (1)
+
simultane-
ously
Change mode of operation / service mode
20.2 Service buttons S1 and S2
Function
Input and reaction
Open/leave the parameter menu
X
Press buttons S1 and S2 simultaneously for longer than 2 s.
LED5 flashes slowly, corresponding to the selected param-
eter level:
Level 1:
1 pulse + 1 s break
Level 2:
2 1 s break
LED1 through LED4 display the parameter.
Parameter selection
X
Briefly press button S2 (+) or button S1 (–).
Switch to value setting
X
Keep button S1 pressed longer than 2 s.
In the value menu, LED5 is off and LED1 through LED4
display the value in accordance with the value table.
Change value
X
Briefly press button S2 (+) or button S1 (-).
Confirm value
X
Press button S1 for longer than 2 s.
Value setting without exiting value change
X
Press button S2 for longer than 2 s.
Reset values to factory settings
X
Set factory settings parameter to
01
.
20.3 Pre-conditions for commissioning
à
Installation is complete.
à
Electrical installation is complete.
à
Sensors are correctly configured and aligned.