ECturn/ECturn Inside
30
Rechargeable battery
17 Rechargeable battery
à
Rechargeable battery ECturn, mat. no. 131473
à
Rechargeable battery ECturn Inside, mat. no. 149496
à
The rechargeable battery is not in the drive when the unit is delivered.
à
The rechargeable battery can be discharged in the delivery state. Therefore the drive has to be operated using
the on-site power supply for at least 24 hours after connection of the rechargeable battery in order for the
rechargeable battery to charge.
à
Rechargeable battery voltage in charged state:
≥
21.6 V (with rechargeable battery unplugged)
à
The rechargeable battery has to be replaced every 2-3 years.
X
Set parameter
ac
for the required behaviour of the drive in the event of an on-site mains voltage failure
(see chapter 21, “Parameter menu”):
à
After a supply voltage failure the drive still carries out the function set with parameter
ac
. Then the drive
switches itself off by disconnecting the connection to the rechargeable battery.
If the NA, AU or DO mode of operation is set, the drive can be activated via the KB input or one f the radio
channels FK1 or FK2. With
ac
=
01
the drive opens and switches off in the open position. With
ac
=
0 2
the
drive opens and closes and switches off in the closing position.
BK
AKKU
-
+
+
-
RD
19,2 V