background image

UNI Stop/Holder

UNI-TJ50BC Series

UNI-TJ51(BF) Series

Sized Closers

Multi-Sized Closers

Installation Instructions

80-9350-2517-010 (06-09)

Non Handed Door Closers

Sized

(Sizes  2,3,4,5,6)

UNI-TJ52BC UNI-TJ152BC
UNI-TJ53BC   UNI-TJ153BC
UNI-TJ54BC   UNI-TJ154BC
UNI-TJ55BC   UNI-TJ155BC
UNI-TJ56BC   UNI-TJ156BC

Multi-Sized

(Sizes 3 thru 6)

UNI-TJ51

UNI-TJ151

(Sizes 1 thru 4)

UNI-TJ51BF

UNI-TJ151BF

CA

UTION

AN INCORRECTLY INSTALLED OR IMPROPERLY
ADJUSTED DOOR CLOSER CAN CAUSE
PROPERTY DAMAGE OR PERSONAL INJURY.
THESE INSTALLATION INSTRUCTIONS SHOULD
BE FOLLOWED TO AVOID THE POSSIBILITY OF
MISAPPLICATION OR MISADJUSTMENT.

CA
UTION

!

!

!

!

NOTE: For special applications a separate door and frame preparation template is packed with these instruction. Use this
instruction sheet for installation sequence and closer adjustments only.
It is recommended that the door, on which the door closer will be installed, be hung on ball bearing hinges. Door must swing
freely.
Door and Frame must be properly reinforced, or use of special fasteners employed, to prevent the mounting screws from pulling
out.
All dimensions are given in inches with corresponding metric dimensions (millimeters) in parenthesis.

Right Hand Door - RH
Left Hand Reverse - LHR

Hinge edge of door

Left Hand Door - LH

Right Hand Reverse - RHR

Right Hand Door - RH
Left Hand Reverse - LHR

Left Hand Door - LH

Right Hand Reverse - RHR

Components

Pinion Cap

Power Adjustment Screw (3/16 Hex Drive)

“BC” Valve

Closer
Size
Stamp

“L” Valve

“S” Valve

Optional Cover

Hinge edge of door

Hinge edge of door

Hinge edge of door

Non Hold Open &

Hold Open (TJ150) Models

Series UNI-TJ50

UL Listed for Fire Doors

Door Stop...Door Closer

Series UNI-TJ150

(On-Off Hold-Open Control) Not UL Listed

Door Stop...Door Holder...Door Closer

2 sex-nuts

Holder Control

Slide Unit

Rod Screws

Main-Arm

Screw

Rod Unit

(Arm Number

Stamp)

Optional Thru-Bolt

&

Grommet Nuts

These installation instructions cover either of the models illustrated.

Summary of Contents for UNI-TJ50BC Series

Page 1: ...door closer will be installed be hung on ball bearing hinges Door must swing freely Door and Frame must be properly reinforced or use of special fasteners employed to prevent the mounting screws from pulling out All dimensions are given in inches with corresponding metric dimensions millimeters in parenthesis Right Hand Door RH Left Hand Reverse LHR Hinge edge of door Left Hand Door LH Right Hand ...

Page 2: ...en rod screws Snap pinion cap in place Adjust closer Typical Installation 9 32 7 00mm thru 3 8 9 50mm door face opposite to closer 7 201 dia or 5 10mm drill 1 4 20 tap 3 8 9 50mm thu 3 16 4 30mm Drill aluminum or wood Hollow metal Frame metal wood 1 4 20 machine screw 14 type A sheet metal screw Fasteners Door Does not apply SNB Does not apply Preparation for Fasteners Hold Open Stop 85 90 95 100 ...

Page 3: ... foot to door Position foot with rod on bottom Reassemble arm Adjust forearm perpendicular at a 90 angle to door Tighten rod screws Snap pinion cap in place Adjust closer Typical Installation Hold Open Stop 85 90 95 100 105 110 90 95 100 105 110 115 7 3 8 6 3 4 6 1 2 187 171 165 Pinion Cap BC Power Adjustment Shaft Main Arm Hold Open Models suffixed H Forearm Arm Screw Rod Unit Arm Number Stamp Ar...

Page 4: ... WILL RESULT Increase Decrease BC Valve Closing Power Control Figure 3 Adjust as required Product is shipped at lowest power setting Power Adjustment Chart DOOR INT EXT INT EXT TJ51 TJ51BF PARALLEL ARM INSTALLATION FULL 360 TURNS OF POWER ADJUSTMENT SHAFT MAXIMUM DOOR SIZE 34 0 85M 36 0 90M 40 1 00M 44 1 10M 48 1 20M 2 2 3 4 5 8 9 12 10 13 3 5 7 5 7 10 NOT RECOMMENDED USE TJ51 14 16 18 360 TURNS M...

Reviews: