48
Input off:
Direct the PTZ camera to another preset point when the triggered input is
off.
Duration to set preset after input off x seconds:
Specify the amount of time the
PTZ camera stays in “Input on” preset point before moving to “Input off” preset point.
For related PTZ settings, see
4.2.1 PTZ Settings
.
Output Setting
Figure 4-14
Select
Enable
to enable the output device. Choose the output signal that mostly suits the
device you are using: N/O (Open Circuit), N/C (Grounded Circuit), N/O Toggle, N/C Toggle,
N/O Pulse or N/C Pulse. For
Toggle
output type, the output will keep going on once it is
triggered until the next trigger. For
Pulse
output type, the output is triggered for the
amount of time you specify in the Trigger Pulse Mode for x Seconds field.
Alarm Settings:
You can choose to automatically activate the configured output device for alarm under
these conditions: video lost, tampering alarm, video recording start (Start Record), video
recording stop (Stop Record), disk write error (Rec Error) and hard disk full (HD Full).