132
9.1.2 Relay Output
The relay outputs on the terminal block only drives a maximum load of 5 volts. Working in
conjunction with the GV-Relay V2 module, it is capable of driving heavier loads. Refer to
the figure and table below to connect the GV-Relay V2 module to the GV-Video Server.
Note:
The GV-Relay module is an optional product.
Output Devices 1-4
Figure 9-2
GV-Relay V2
I/O Terminal Block
DO 1
Pin 1
DO 2
Pin 3
DO 3
Pin 5
DO 4
Pin 7
+ 5V
Pin 9
Note that you don’t need to use the DC 5V connector on the GV-Relay V2 module for
power supply, since the power is supplied from the GV-Video Server.