3-4.2.12 Re place ment of Sin gle Vi sor As sem bly
MA TE RIALS RE QUIRED
QUAN TITY
DE SCRIP TION
REF ER ENCE NUMBER
1
Sin gle vi sor as sem bly, EEK-4, me dium
or
85B7024-1
1
Sin gle vi sor as sem bly, EEK-4, large
or
85B7024-2
1
Sin gle vi sor as sem bly, EEK-4, X-large
(ex tra large)
85B7024-3
NOTE
When dis as sem bling the dual vi sor as sem bly, note the or der of parts;
you will as sem ble the dual vi sor in the same man ner.
1. Ro tate the vi sor
lock as sem bly a
quar ter turn so that
the vi sor key will
clear the vi sor
cut out and the
hous ing slot; lift
the lock as sem bly
away from the
vi sor as sem bly.
2. Slide the vi sor
out of the tracks.
3. Re move the six
screws (three
on each side)
at tach ing the
dual vi sor
hous ing, tracks,
and spac ers
to the hel met.
3-22
Fig ure 3-22. Sin gle Vi sor As sem bly
VISOR
CUTOUT
HOUSING
LOCK
ASSEMBLY
KEY
SCREW
TRACK
POST
OUTER
SPACER
INNER
SPACER