6. MANUAL OPERATION
If the gate has to be moved manually due to a power cut or
operator failure, proceed as follows:
Cut electrical power with the differential switch, also in the
event of a power cut.
Insert the manoeuvering key in its seat located a the top of
the operator (Fig.17).
Turn the key in the direction of the arrow (Fig.18) – the release
lever opens slightly to facilitate meshing.
Rotate the release lever until it stops, (Fig.19).
This operation may require some force.
Move the leaf by hand.
7. RESTORING NORMAL OPERATION MODE
Procedure for restoring normal operation of the motor:
Make sure that the system is not powered, using the differen-
tial switch.
Close the release lever (Fig.20).
Exert light pressure to attach the lever.
Move the leaf by hand until it stops.
Supply power to the system.
Command a couple of work cycles to verify correct restoration
of all functions.
Fig. 17
Fig. 18
Fig. 19
Fig. 20
8. MAINTENANCE
To ensure correct long-term operation and a constant level of sa-
fety, we advise you to generally control the system every 6 months.
In the “User’s Guide” booklet, there is a form for recording jobs.
9. SPECIAL APPLICATIONS
Applications other than those described in this manual are EX-
PRESSLY PROHIBITED.
0. REPAIRS
The User must not in any way attempt to repair or to take direct
action and must solely contact qualified GENIUS personnel or
GENIUS service centres.
. ACCESSORIES
For accessories, consult the GENIUS catalogue.