Model FL3102
18
The WARN relay contact ratings are 8A @ 250VAC and 8A @ 30VDC.
CAUTION –
For all relay connections see Figure 24.
Figure 24 Relay Contacts
3.4.3 Fault Relay
TB2, Term 8 = FLT C
TB2, Term 9 = FLT 1
TB2, Term 10 = FLT 2
Description: These connections are to the SPDT FAULT relay. The FAULT
output configuration is normally energized and non-latching. This is the standard
output configuration and it cannot be changed.
The FAULT circuit will be activated during the time-out function, a low power or
loss of power condition, and during a failed COPM check. During these
conditions, the FAULT relays will de-energize and the analog output signal will
drop to 0 mA (2mA for COPM Faults) for the duration of the FAULT.
Fault Relay
TB2, Term 8 = FLT C = Fault Common
Normally energized
TB2, Term 9 = FLT 1 = Normally Open
TB2, Term 10 = FLT 2 = Normally Closed
The FAULT relay contact ratings are 8A @ 250VAC and 8A @ 30VDC.
CAUTION –
For all relay connections see Figure 24.