Inch OD
Outside diame-
ter
Wall thickness
Inside diameter
Outside diame-
ter acc. to BS
4825
1.5"
38.1
1.65
34.8
X
2"
50.8
1.65
47.5
X
2.5"
63.5
1.65
60.2
X
3"
76.2
1.65
72.9
X
4"
101.6
2.11
97.38
X
6"
152.4
2.77
146.86
X
Inch IPS
Outside diame-
ter
Wall thickness
Inside diameter
Outside diame-
ter according to
DIN EN ISO 1127
2"
60.3
2
56.3
X
3"
88.9
2.3
84.3
X
4"
114.3
2.3
109.7
X
6"
168.3
2.77
162.76
X
3.2.5 Lubricants
Lubricant designation
Material no.
Rivolta F.L.G. MD-2 (1000 g)
413-071
Rivolta F.L.G. MD-2 (100 g)
413-136
30 / 106 - 3.2 Technical data
0000000576 - 001 - EN-GB