background image

1

®

Bendix

®

 TC-6

 Trailer Control Brake Valve

SD-03-821

FIGURE 1

DESCRIPTION

The Bendix

®

 TC-6

 trailer control brake valve is normally

used to operate the trailer brakes independently of the tractor
brakes. It may be used, however, wherever a hand controlled
pressure graduation function is desired.

The TC-6

 valve is handle operated and is designed for panel

or dog house mounting.

The TC-6

 trailer control brake valve is not designed for use

as a parking brake control and should never be used to
hold the brakes applied when the operator leaves the vehicle.

OPERATION

APPLYING

When the handle (item 10) is pulled through its 75° arc, the
roller cam (item 11) is rotated accordingly. The cam action
forces the cam follower (item 9) downward, compressing
the graduating spring (item 6) and creating a force on the
plunger (item 12) which depresses the inlet valve (item 2)
and delivers air under pressure to the delivery port.

HOLDING

As delivery pressure builds up in the delivery port, it is also
effective under the plunger (12) causing it to balance the
force of the graduating spring (6) until the inlet valve (2) is
seated against its seat in the body and is also seated against
the plunger (12), thus preventing the delivery air from
exhausting through the center of the plunger (12),
maintaining the desired pressure in the delivery line.

RELEASING

When the handle is released or moved to its release position,
the cam follower (9) is permitted to rise, opening the exhaust
passage and allowing the air pressure in the delivery line to
exhaust out the exhaust port.

PREVENTIVE MAINTENANCE

Important:  Review the Bendix Warranty Policy before
performing any intrusive maintenance procedures. A warranty
may be voided if intrusive maintenance is performed during
the warranty period.

FIGURE 2

EXHAUST

DELIVERY

SUPPLY

KNOB

13

11

14

8

10

9

7

6

12
5

15

4

2

3

1

16

Summary of Contents for TC-6 BRAKE VALVE

Page 1: ... which depresses the inlet valve item 2 and delivers air under pressure to the delivery port HOLDING As delivery pressure builds up in the delivery port it is also effective under the plunger 12 causing it to balance the force of the graduating spring 6 until the inlet valve 2 is seated against its seat in the body and is also seated against the plunger 12 thus preventing the delivery air from exh...

Page 2: ... seconds With the valve fully applied leakage at the exhaust line should not be greater than 175 SCCM 1 bubble in 3 seconds If the valve does not function as described or if the leakage is excessive it is recommended that it be returned to the nearest Bendix authorized distributor for a factory remanufactured valve under the exchange plan If this is not possible the valve can be repaired with genu...

Page 3: ... head cap screws 14 Place the rubber knob back on the handle Reinstall the valve on the vehicle and test per operating leakage checks in this manual WARNING PLEASE READ AND FOLLOW THESE INSTRUCTIONS TO AVOID PERSONAL INJURY OR DEATH When working on or around a vehicle the following general precautions should be observed at all times 1 Park the vehicle on a level surface apply the parking brakes an...

Page 4: ...ed manufacturer s recommended pressures 7 Never connect or disconnect a hose or line containing pressure it may whip Never remove a component or plug unless you are certain all system pressure has been depleted 8 Use only genuine Bendix replacement parts components and kits Replacement hardware tubing hose fittings etc must be of equivalent size type and strength as original equipment and be desig...