Designation
Description
Valve
0 to 45 °C (32 to 113 °F), standard
< 0 °C (32 °F): Use control air with low dew point.
Protect valve rods against freezing.
< −15 °C: no solenoid valves in the control top
< +50 °C: no solenoid valves in the control top
Proximity switch
-20 to +80 °C (-4 to +176 °F)
Control top T.VIS M-20, M-15, A-15, P-15
-20 to +55 °C (-4 to +131 °F)
Product temperature and operating temperature
depending on the sealing material
Designation
Description
Air hose
●
Metric
Material PE-LD
Outside Ø 6 mm
Inside Ø 4 mm
●
Inch
Material PA
Outside Ø 6.35 mm
Inside Ø 4.3 mm
●
Control air
acc. to ISO 8573-1
●
Solid particle content:
Quality class 6
Particle size max. 5 µm
Particle density max. 5 mg/m
3
●
Water content:
Quality class 4
max. dew point +3 °C
If the unit is used at higher altitudes or at low am-
bient temperatures, the dew point must be adap-
ted accordingly.
●
Oil content:
Quality class 3
preferably oil free
max. 1 mg oil to 1 m
3
air
Control air pressure
6 bar (87 psi), max. 8 bar (116 psi) configuration
with standard drive
Alternative combinations of product pressure and
control air pressure on request
Special model: min. 4.8 bar, max. 6 bar
Pneumatic support: spring side max. 6 bar
26 / 106 - 3.2 Technical data
0000000576 - 001 - EN-GB
Summary of Contents for ECOVENT N ECO Series
Page 6: ...6 106 Table of Contents 0000000576 001 EN GB...
Page 9: ...1 4 Declarations of conformity 1 4 Declarations of conformity 9 106...
Page 12: ...12 106 1 4 Declarations of conformity 0000000576 001 EN GB...
Page 20: ...20 106 2 10 Emergency measures 0000000576 001 EN GB...
Page 38: ...38 106 5 6 Electrical connection with T VIS control top 0000000576 001 EN GB...
Page 42: ...42 106 7 2 Shutdown 0000000576 001 EN GB...
Page 82: ...82 106 9 7 Maintenance 0000000576 001 EN GB...
Page 84: ...84 106 9 7 Maintenance 0000000576 001 EN GB...
Page 98: ...98 106 12 2 Spare parts lists 0000000576 001 EN GB...
Page 103: ...2 20 10 2022 221MBL003579DE_4 13 2 Dimensions sheet Actuator ECO E 103 106...