Spring-to-close valve (NC) without control head T.VIS
INFO
Mounting step: remove the clamp connection between the housing and
lantern
Tools
●
Open-ended wrench
1.
Pressurize the actuator - with com-
pressed air, max. 8 bar (air connection
61).
®
The valve disk is raised.
Valve insert lowers into the hous-
ing
2.
Mount the clamp connection (43) be-
tween the housing and lantern (9).
®
Observe torques, see
3.
Depressurize the actuator (air connec-
tion 61).
®
The valve disk is lowered.
43
9
4.
Optional version with INI holder and blanking plate:
4.1
Screw the mounting for the proximity switch (C) into the actuator using the
jaw wrench on the wrench flat surface (C3).
4.2
Screw the switch bar (139) into the mounting for proximity switch (C) on the
wrench flat surface (139.1) using a jaw wrench (a/f 17).
4.3
Fit the proximity switches (C1, C2).
®
Observe torques, see
.
Þ
The clamp connection is mounted.
72 / 106 - 9.6 Installing the valve
0000000576 - 001 - EN-GB
Summary of Contents for ECOVENT N ECO Series
Page 6: ...6 106 Table of Contents 0000000576 001 EN GB...
Page 9: ...1 4 Declarations of conformity 1 4 Declarations of conformity 9 106...
Page 12: ...12 106 1 4 Declarations of conformity 0000000576 001 EN GB...
Page 20: ...20 106 2 10 Emergency measures 0000000576 001 EN GB...
Page 38: ...38 106 5 6 Electrical connection with T VIS control top 0000000576 001 EN GB...
Page 42: ...42 106 7 2 Shutdown 0000000576 001 EN GB...
Page 82: ...82 106 9 7 Maintenance 0000000576 001 EN GB...
Page 84: ...84 106 9 7 Maintenance 0000000576 001 EN GB...
Page 98: ...98 106 12 2 Spare parts lists 0000000576 001 EN GB...
Page 103: ...2 20 10 2022 221MBL003579DE_4 13 2 Dimensions sheet Actuator ECO E 103 106...