Spring-to-close valve (NC) with control head T.VIS
INFO
Mounting step: remove the clamp connection between the housing and
lantern
Tools
●
Philips screwdriver
1.
Pressurize the actuator – with com-
pressed air (max. 8 bar) - by activating
the solenoid valve Y1 at the manual
operation element S.
®
Valve disk is raised.
Valve insert lowers into the hous-
ing.
2.
Mount the clamp connection (43) be-
tween the housings and lantern (9).
®
Observe torques, see
.
3.
Depressurize the actuator by deacti-
vating the solenoid valve Y1 at the
manual operation element S.
®
The valve disk is lowered.
4.
Attach the hood (7) to the control top
using a philips screwdriver.
®
Observe torques, see
.
43
25
Y1
S
7
43
9
Figure 9-3 - Version with 2 housings
Þ
The clamp connection is mounted.