5.
Use the insertion tool to press in the
V-ring – press in evenly at several op-
posite points along the circumference.
6.
Insert the V-ring evenly.
Þ
V-ring has been exchanged.
INFO
Used seals must not be used again, since the proper function of the
seal can then no longer be ensured.
9.7.2.2
Replacing more seals
Prerequisites
●
The valve has been removed, see
●
Insert V-Ring without grease. To facilitate fitting, use water with a drop of
washing-up liquid to remove the surface tension. In order that no rust is trans-
ferred, the washing-up liquid solution must be made up in a ceramic, plastic, or
stainless steel container.
INFO
Functional and running surfaces of the valve disks must not get damaged.
1.
Replace all the other seals identified in the spare parts lists. See spare parts list
Þ
Seals have been replaced.
INFO
Used seals must not be used again, since the proper function of the
seal can then no longer be ensured.
80 / 106 - 9.7 Maintenance
0000000576 - 001 - EN-GB
Summary of Contents for ECOVENT N ECO Series
Page 6: ...6 106 Table of Contents 0000000576 001 EN GB...
Page 9: ...1 4 Declarations of conformity 1 4 Declarations of conformity 9 106...
Page 12: ...12 106 1 4 Declarations of conformity 0000000576 001 EN GB...
Page 20: ...20 106 2 10 Emergency measures 0000000576 001 EN GB...
Page 38: ...38 106 5 6 Electrical connection with T VIS control top 0000000576 001 EN GB...
Page 42: ...42 106 7 2 Shutdown 0000000576 001 EN GB...
Page 82: ...82 106 9 7 Maintenance 0000000576 001 EN GB...
Page 84: ...84 106 9 7 Maintenance 0000000576 001 EN GB...
Page 98: ...98 106 12 2 Spare parts lists 0000000576 001 EN GB...
Page 103: ...2 20 10 2022 221MBL003579DE_4 13 2 Dimensions sheet Actuator ECO E 103 106...