REVISION HISTORY
M60 MOTOR PROTECTION SYSTEM – INSTRUCTION MANUAL
D-3
D
Table D-3: Major changes for M60 manual version AE3 (English)
Table D-4: Major changes for M60 manual version AE1 (English)
---
Added PEAP-GTC and PAP protocols for authenticating user logins when using a RADIUS server. Added to Settings > Product
Setup > Security > RADIUS Authentication Method and to Modbus memory map and F codes.
---
Updated Contact Inputs from 96 to 120 and Contact Outputs from 64 to 72 in Product Description in chapter 2 and FlexLogic
operands table in chapter 5
---
Updated Ground Instantaneous Overcurrent element number from 6 to 8 in FlexLogic operands table, settings, features per
product table, Modbus memory map
---
Updated Neutral Instantaneous Overcurrent element number from 4 to 12 in FlexLogic operands table, settings, features per
product table, Modbus memory map
---
Updated Neutral Time Overcurrent element number from 2 to 6 in FlexLogic operands table, settings, features per product
table, Modbus memory map
---
Updated Phase Instantaneous Overcurrent element number from 8 to 12 in FlexLogic operands table, settings, features per
product table, Modbus memory map
---
Updated Phase Time Overcurrent element number from 4 to 6 in FlexLogic operands table, settings, features per product
table, Modbus memory map
---
Updated Current CT Settings number from 4 to 6 in FlexLogic operands table, settings, features per product table, and
Modbus memory map
---
Updated Ground Instantaneous number from 6 to 12 in FlexLogic operands table, settings, features per product table,
Modbus memory map
---
Updated Ground Time Overcurrent number from 4 to 6 in FlexLogic operands table, settings, features per product table,
Modbus memory map
3-36
Updated RS422 and Fiber Interface Connection figure for the clock channels (from 7a and 7b to 1a and 1b)
3-67
Added Connect to a D400 Gateway section
4-43
Updated LED Labelling instructions for the new Front Panel Label Designer
4-50
Added Standard Front Panel section for labelling LEDs and pushbuttons
5-106
Added USB Port section to enable/disable the USB port on the graphical front panel
5-120
Updated User-programmable Pushbuttons section as per specifications
5-144
Updated Breakers section as per specifications
5-149
Updated Disconnect Switches section as per specifications
9-
Added Theory of Operation chapter to include Saturation Detector section
10-5
Added Convert Device Settings section
10-7
Added Copy Settings to Other Device section
10-15
Added Replace Front Panel section for retrofit with the new graphical front panel
Page
Description
---
General revision
2-
Updated order codes
9-5
Added Copy Settings to Other Device section
Page
Description
---
General revision
---
Added routable GOOSE content in chapters 2 and 5
3-36
Updated RS422 and Fiber Interface Connection figure for the clock channels (from 7a and 7b to 1a and 1b)
4-
Added Engineer content
5-
Updated IEC 61850 content
A-
Updated FlexAnalog table for most UR products
Page
Description
Summary of Contents for M60
Page 9: ...TABLE OF CONTENTS M60 MOTOR PROTECTION SYSTEM INSTRUCTION MANUAL ix INDEX ...
Page 10: ...x M60 MOTOR PROTECTION SYSTEM INSTRUCTION MANUAL TABLE OF CONTENTS ...
Page 552: ...5 344 M60 MOTOR PROTECTION SYSTEM INSTRUCTION MANUAL TESTING CHAPTER 5 SETTINGS 5 ...
Page 660: ...iv M60 MOTOR PROTECTION SYSTEM INSTRUCTION MANUAL ABBREVIATIONS ...