48
Pressure Sensor
Pressure Sensor Hose
7. Disconnect IMC wire harnesses and remove IMC
board.
RJ45 Board
Operating Voltage:
12 VDC & 7.5 VDC
Location:
See RJ45 Board Location on page 35.
The RJ45 is used to interface the washer control
board to other types of computer systems. The
RJ45 board re12 VDC, +7.5 VDC, COMM and
DC GND to operate. These voltages are generated
on the IMC board and supplied to the RJ45 board
through the UI board.
RJ45 Board Strip Circuit
IMC J101-3
IMC J101-2
L1
N
IMC J103-4
IMC J103-3
IMC J103-2
IMC J103-1
DC GND
COMM
+7.5 VDC
+12 VDC
RJ45 J203-3
RJ45 J203-2
RJ45 J203-1
UI J201-1
UI J201-3
UI J201-2
UI J201-5
UI J201-6
UI J201-7
UI J201-8
DC GND
COMM
+12 VDC
IMC Board
UI Board
RJ45 Board Removal
1. Disconnect power to the unit.
2. Remove the control panel. (See
Control Panel
Removal
)
3. Remove the top panel. (See
Top Panel Removal
)
4. Disconnect the RJ45 wire harness.
5. Remove the RJ45 board mounting screw.
1/4” Hex