62
Thermistor
Operating Voltage
: 5 VDC
Resistance
: See Chart Below
Location:
See Thermistor Location on page 36.
Thermistor Chart
36.5 k
32 °F
14.7 k
68 °F
12.0 k
77 °F
9.8 k
86 °F
8.0 k
95 °F
6.6 k
104 °F
.5 k
257°F
Thermistor Tests
1. Enter service mode.
2. Run Test 13.
3. Verify temperature change while the heater is
on.
Thermistor Removal
1. Disconnect power to the unit.
2. Remove the rear cover. (See
Rear Cover Remov-
al
).
3. Disconnect the thermistor harness.
4. Remove thermistor.
Note
: When reinstalling the thermistor ensure the
thermistor O-Ring is in place.
Dispenser Assembly
Flow Restricter
O-Ring
Location:
See Dispenser Assembly Location on page
35.
The dispenser assembly is used to dispense deter-
gent, bleach and fabric softener into the wash load.
Additives are placed in the detergent dispenser
drawer (shown below) where they will be
fl
ushed
into the wash at the appropriate time.
Water is routed to the dispenser assembly any time
a water valve is energized. A water diverter is used
to direct the incoming water to one of four compart-
ments as shown below.
Diverter
Pre-w
ash
Main Wash
Fabric Softener
Bleach