25
Test 25
Low Flow (Steam)
Water Valve Test
• Press
the
Start
key to begin the test.
• After the door locks the low
fl
ow water valve is energized and the
pressure sensor frequency is displayed in the display with 1 decimal
point of resolution. (i.e.: XX.X Hz. See Pressure Sensor for frequencies.)
Note
: The control will continue
fi
lling until the over
fl
ow level is reached,
at that time the water valves will be turned o
ff
and the drain pump will be
energized until the tub is drained to empty
Test 26
Recirculation
Pump Test
• Press
the
Start
key to begin the test.
• The door locks and the cold water valve is energized until the main
water level is reached, at that time the cold water valve will be
de-energized and the recirculation pump will be energized.
Note
: If the water level falls below the main water level, the recirculation
pump will de-energized.
Test 27
Overnight Dry
Fan Test
• Press
the
Start
key to begin the test.
• The door locks, the overnight dry fan is energized, and
onr
is displayed
in the display.
Consumer Mode
Consumer mode is a special mode that allows the consumer to see fault codes.
Consumer Mode Entry
• The control must be in the idle state to enter consumer mode.
• Simultaneously press and hold Power, Soil Level and Temperature for 3 seconds.
Consumer Mode Navigation
• Upon entering consumer fault code mode the control will display the number in HEX format.
• Fault codes will only be displayed if they are active.
• Pressing the Start key displays the next fault code in the fault code log.
• If there are no fault codes in the log, the control will display “
―
” on the seven segment display.
Consumer Mode Exit
• Press the Power key.
• The control will return to the idle state 30 minutes after entering consumer fault code mode.
• Disconnect power from the appliance.