Test 12
Drain Pump Test
Press the
Start
key to begin the test.
Drain pump comes on and
P1
is displayed in the display.
Test 13
Heater Test
• Press the
Start
key to begin the test.
• Water temperature in °F is displayed in the display.
• If water is present at the start of the test, the tub will be drained to
empty. Otherwise, the tub will
fi
ll to the appropriate water level and the
heater will be turned on.
Note
: If at any time during the test the water level gets too low, the heater
will be turned o
ff
and the water valve will be turned on until the water
level reaches a safe heater operating temperature, then the heater will be
turned back on.
Test 14
Door Lock Test
• Press the
Start
key to begin the test.
• The door will lock and
LC
will be displayed in the display.
• Pressing
the
Start
key again will unlock the door and
UL
will be
displayed in the display.
Test 15
Out of Balance
Test
• Press
the
Start
key to begin the test.
• If water is present at the start of the test, the tub will be drained to
empty.
• Washer spins at 100 RPM and OOB value will be displayed in the
displayed will display.
Test 16
Pressure Sensor
Test
• Press
the
Start
key to begin the test.
• If water is present at the start of the test, the tub will be drained to
empty.
• Hot and cold water valves are energized and the pressure sensor
frequency is displayed in the display with 1 decimal point of resolution.
(i.e.: XX.X Hz. See Pressure Sensor for frequencies.)
Note
: The control will continue
fi
lling until the over
fl
ow level is reached,
at that time the water valves will be turned o
ff
and the drain pump will be
energized until the tub is drained to empty.
Test 17
Flow Meter Test
• Press the
Start
key to begin the test.
• If water is present at the start of the test, the tub will be drained to
empty.
• Hot and cold water valves are energized and the
fl
ow rate in liters/
minute is displayed in the display with 1 decimal point of resolution.
(i.e.: XX.X L/M)
Note
: The control will continue
fi
lling until the over
fl
ow level is reached,
at that time the water valves will be turned o
ff
and the drain pump will be
energized until the tub is drained to empty.
Test 18
UI Critical
Software Version
Check
• Press
the
Start
key to begin the test.
•
Major software version
of the UI software is displayed in the display
for 1 second and the
Extra Heavy LED
is on.
•
Minor software version
of the UI software is displayed in the display
for 1 second and the
Heavy LED
is on.
The display will continue to toggle between the 2 versions until the user
exits the test.