66
08/24/2016
6. Edition, ID No.: 37020GB-F
Operating Manual ERESCO MF4 Type Series
Copyright by GE Sensing & Inspection Technologies GmbH Bogenstrasse 41 D - 22926 Ahrensburg
9
Replacing the high voltage lamp at the digital control unit ERESCO MF4 control
High voltage lamp failure at the operation module results in message
53:
High voltage lamp
defective and the high voltage is immediately switched off.
Proceed as follows to replace the high voltage lamp:
1. Unscrew the yellow lamp cover
2. Preferably use the lamp extractor (size T1½)
to remove the defective lamp with holder:
Alternatively: Rubber hose, long-nosed pliers,
forceps
Lamp extractor: ID No. 9456540
Bulb:
ID No. 9030420
3. Lamp covers are installed in reverse order.
When inserting the yellow cap, make sure
that the high voltage arrow is pointing
downwards.