![GE ERESCO 160 MF4-R Operating Manual Download Page 27](http://html.mh-extra.com/html/ge/eresco-160-mf4-r/eresco-160-mf4-r_operating-manual_127707027.webp)
27
08/24/2016
6. Edition, ID No.: 37020GB-F
Operating Manual ERESCO MF4 Type Series
Copyright by GE Sensing & Inspection Technologies GmbH Bogenstrasse 41 D - 22926 Ahrensburg
2.4
Power mode
In power mode, the shortest exposure time that can be achieved with the maximum tube
output is calculated.
To switch on the power mode, parameter input must occur as described in section 2.3
according to the
exposure diagram (see appendix) in the following order:
Example:
1. kV = 90,
2. mA = 4.5,
3. min = 5.0.
For
power optimisation, press the F5
key
P
:
The unit calculates the shortest
exposure time that can be achieved with the maximum
tube power.
The shortest exposure time set by the unit is
30 sec.
NOTE:
In case of low mains voltage (< 204 V or < 107 V), the nominal values cannot
be achieved, depending on the output power.
The unit then switches off with message 124: reduce power
.
Remedy:
Reduce the power by approx. 20% and increase the exposure
time correspondingly.