47
08/24/2016
6. Edition, ID No.: 37020GB-F
Operating Manual ERESCO MF4 Type Series
Copyright by GE Sensing & Inspection Technologies GmbH Bogenstrasse 41 D - 22926 Ahrensburg
09 Operat. history
Up to 256 data records (0-255) can be requested about the history.
Use the
or
key to select and display the previous or next data record. Press the
or
key to call the next or previous 10 data records.
The data record number (
No
.), the operating mode (
M
,
W
,
P
), the
kV
nominal and actual
value
, the
mA nominal and actual value
, the high voltage status f (X-Ray ON (
X
) or X-Ray
OFF) and a possible related message (
) are always displayed.
Press the
F3
key to call a further mask which, in addition
to the permanently displayed
values (see above), also shows the following measured values
:
The mains voltage (
V~
), the cascade temperature (
°C/°F
), the gas pressure of the radiating
unit (
bar) and the temperature of the power stage (°C/°F
).
Press the
F4
e
key to call a further mask which, in addition to the permanently displayed values
(see above), also shows the timer nominal and actual value (
) and the program number
( ):
Moreover, this mask displays the
Date
and
Time
of the event.
Data record number
Operating mode
kV nominal and actual value
mA nominal and
actual value
X-Ray ON (X) / X-Ray OFF
Message
Data record number 000-255
Mains voltage
Cascade temperature
Gas pressure
Power stage temperature