Specifications
8-5
September 2004
Transducer
Specifications (cont.)
Clamp-on Transducers
Type:
Shear wave or longitudinal wave.
Temperature Range
Standard:
-40
o
to 212
o
F (-40
o
to 100
o
C).
Optional (overall range):
-328
o
to 500
o
F (-200
o
to 260
o
C).
Frequency:
Standard:
1 MHz.
Optional:
500 MHz, 2 MHz, or 4 MHz.
Mounting:
SS chain or strap, welded or magnetic slide-track mounting
fixtures.
Housing:
Standard:
None (splashproof).
Optional:
Explosion-proof, Div. 1, Class 1, Group C&D,
INIEX-certified EEx d IIC T6 or weatherproof (NEMA 4, IP65).
Other Options:
Transducers for special applications; fixtures; no organic bonds or
insulators; cooling jackets for high temperatures. Please consult
GE Infrastructure Sensing for details.
Pipe Size and Materials
Wetted Transducers
Materials:
All metals and most plastics. (Consult the factory for concrete,
glass and cement.)
Pipe Sizes:
Inside Diameter: 0.04 to 200 in. (1 mm to 5 m) and larger.
Clamp-on Transducers
Materials:
316 SS and most plastics. (Consult the factory for concrete,
composite materials and highly corroded or lined pipes.)
Pipe Sizes:
Outside Diameter: 0.5 to 200 in. (12.7 mm to 5 m) and larger.
Pipe Wall Thickness:
Up to 3 in. (76.2 mm).
Summary of Contents for AquaTrans AT868
Page 8: ...Chapter 1 ...
Page 24: ...Chapter 2 ...
Page 60: ...Chapter 3 ...
Page 66: ...Chapter 4 ...
Page 72: ...Chapter 5 ...
Page 77: ...Chapter 6 ...
Page 88: ...Chapter 7 ...
Page 98: ...Chapter 8 ...
Page 106: ...Appendix A ...
Page 112: ...Appendix B ...
Page 113: ...CE Mark Compliance Introduction B 1 EMC Compliance B 1 LVD Compliance B 2 ...
Page 116: ...Appendix C ...
Page 117: ...Data Records Site Data C 1 ...
Page 122: ...Appendix D ...
Page 123: ...Measuring P and L Dimensions Measuring P and L D 1 ...
Page 126: ...Appendix E ...
Page 127: ...Service Record Introduction E 1 Data Entry E 1 Diagnostic Parameters E 3 ...
Page 131: ...Appendix F ...