2. Establish a local VistaNET connection to the unit. In the Unit View, click on
Paste
button (available at the bottom of the Unit View).
3. Click on the
Configure
button (available at the bottom of the Unit View).
4. To ensure that all the parameters got properly stored into the unit, click on the
Paste
button again and check if the Configure button remains inactive. If not,
click on the
Configure
button. Repeat this sequence until the
Configure
button remains inactive upon the
Paste
action. This shall be done for each
tab with at least one configurable field, starting from the Main tab.
5. Connect the CBW port cable(s) to the Line Port(s) on the unit's top plate.
Adding ETHER-1000 Unit to a System in Service
WARNING
The ETHER-1000 firmware Version 3 is not backwards compatible with
Version 1. Before installing a V3 unit into a system with ETHER-1000 V1
units, all existing ETHER-1000 units need to be upgraded to V3. See
Appendix F for details.
Before installation:
a) Ensure that a pair of appropriate CBW cables is available (see Table 3 on
page 53). (Only one CBW cable is required at the end of a linear system.)
b) Locate the CBW port(s) on the OC-N JMUX unit(s) to which the ETHER-1000
unit is to be connected. The selected port(s) must support the required CBW
mode of operation (see notes under Table 3 on page 53). Note that the same
CBW port (e.g. CBW-F) must be used on both OC-N units. Also note that
one of the two Line ports may be alternatively connected to another ETHER-
1000 unit‟s Line port (cascading).
c) Ensure that the shelf slots selected for ETHER-1000 unit installation are
within reach of the CBW cables connected to the selected OC-
N JMUX units‟
CBW ports.
d) Ensure there is enough power on the shelf.
Note:
Depending on the number and type of SFP transceivers installed, the
typical ETHER-1000 unit power consumption may range from 8 to 14 W. This
sometimes requires adding a third power supply unit in the shelf.
Installation:
1. Install the ETHER-1000 unit paddleboard on the shelf backplane (refer
Paddleboard Installation
information earlier in this section). Ensure that the
JVT/DS0 channel bus extender (087-86430-90) is not installed in the
backplane underneath nor on either side of the paddleboard.