342-86400-498PS
Issue 1.2
April 2012
Page 131
Copyright
GE Multilin Inc. 2010-2012
Note:
Any D-PVLAN VID modifications in the Advanced tab are common
for all local P-Trunk ports. The modified D-PVLAN VIDs are used only
locally (by the ETHER-1000
„LAN‟ switch).
Note:
VistaNET does not allow for assigning the same VID to multiple
D-PVLANs. It also prevents the user from swapping the default VIDs
between D-PVLANs.
CAUTION
The user must ensure that none of the modified D-PVLAN VIDs are
matching any of the QVLAN IDs used on local Q-Access and
Q-Trunk ports. If this engineering rule is violated, an alarm is
produced and the affected D-PVLAN VID is displayed in red to
indicate possible traffic misrouting.
Defaults
To set all D-PVLAN VIDs to factory default values, click the
Defaults
button and then
Configure
. This action cannot be undone.